Description of the method. Authors: A. Schloegl, C. Vidaurre Downsampling to 128Hz - extract each possible bipolar channels (496) + 32 monopolar channel. From each channel extract the following parameters: adaptive estimates of autoregressive model parameters with non-zero mean. A model order of p = 3 is used. Alpha (10-12Hz) and Beta (16-24Hz) bandpower The parameters AAR(3)+adaptive mean+BP(alpha)+BP(beta) of each single were used to estimated a statistical classifier. the channel with the best separability was selected SUBJ 1: #28 - #10 SUBJ 2: #10 - #2 SUBJ 3: #26 (monopolar) To calculate the classification on the test set, only the parameters of the best channels were classified using linear discriminant analysis.